Specifications

-Accuracy ± 0.12 in. (3 mm)

-Repeatability ± 0.04 in. (1 mm)

-Measurement Range Up to 164 ft (50 m)

-Operating Pressure Full vacuum to 5000 psi (Full vacuum to 345 bar)

-Operating Temperature -320 to 752 °F (-196 to 400 °C)

-Communication Protocol 4-20 mA/HART®, Foundation™ Fieldbus, Modbus®

-Safety SIL 2 IEC 61508 certification ; TÜV tested and WHG approved for overfill prevention

-Diagnostics Enhanced diagnostics enabling proactive maintenance

-Probe Types Rigid single lead, Segmented single lead, Flexible single lead, Rigid twin lead, Flexible twin lead, Coaxial, PTFE coated probes, Vapor probe

Features

 

-Direct Switch Technology gives increased sensitivity, high reliability, and long measurement ranges

-Signal Quality Metrics gives you the ability to work proactively with your level instrumentation

-Probe End Projection offers greater level measurement reliability

-Dynamic Vapor Compensation for improved plant heat rate

-Verification reflector for unique level transmitter verification