<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PRESSURE REDUCER VALVE &#8211; VIBTIS</title>
	<atom:link href="https://www.vibtis.al/product-category/water-supply-sewerage-and-wwts/potable-water/valves-and-equipment/dci-valves-and-equipment/pressure-reducer-valve/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.vibtis.al</link>
	<description>Turnkey Solution - Investment - Services</description>
	<lastBuildDate>Sun, 09 Sep 2018 11:41:14 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.0.6</generator>
	<item>
		<title>014-00 Safety / pressure retention valve</title>
		<link>https://www.vibtis.al/products/014-00-safety-pressure-retention-valve/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Sun, 09 Sep 2018 11:41:14 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=5250</guid>

					<description><![CDATA[Description:
The relieving or retention pressure of the safety / pressure retention valve is infinitely adjustable via the pilot valve between 2-12 bar. Any excessive system pressure is relieved via the main valve opening quickly. Closing is effected slowly to avoid water hammers.

Use:
- Protection of the system from overpressure (safety valve)
- Maintaining the preset mains system pressure in the upstream piping network (pressure retention valve)

Minimum inlet pressure: 1 bar
Minimum pressure difference between inlet and outlet pressure: 1 bar

For rating, please specify the following:
- Flow (min., med., max.)
- Inlet pressure (P1 side)
- Retention pressure and/or relieving pressure (P2 side)
- Holding pressure / back pressure

Components:
1: main valve
2: ball valve (A, B)
3: filter
4: orifice
5: throttle check valve
6: pilot valve
7: manometer with ball valve
8: optical position indicator with vent plug (option: electric position indicator, opening limiter)
<div class="text-expand-footer text-center"></div>]]></description>
										<content:encoded><![CDATA[Description:
The relieving or retention pressure of the safety / pressure retention valve is infinitely adjustable via the pilot valve between 2-12 bar. Any excessive system pressure is relieved via the main valve opening quickly. Closing is effected slowly to avoid water hammers.

Use:
- Protection of the system from overpressure (safety valve)
- Maintaining the preset mains system pressure in the upstream piping network (pressure retention valve)

Minimum inlet pressure: 1 bar
Minimum pressure difference between inlet and outlet pressure: 1 bar

For rating, please specify the following:
- Flow (min., med., max.)
- Inlet pressure (P1 side)
- Retention pressure and/or relieving pressure (P2 side)
- Holding pressure / back pressure

Components:
1: main valve
2: ball valve (A, B)
3: filter
4: orifice
5: throttle check valve
6: pilot valve
7: manometer with ball valve
8: optical position indicator with vent plug (option: electric position indicator, opening limiter)
<div class="text-expand-footer text-center"></div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Threaded Pressure Reducing Valve</title>
		<link>https://www.vibtis.al/products/threaded-pressure-reducing-valve/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Sun, 09 Sep 2018 11:39:35 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=5248</guid>

					<description><![CDATA[Pressure reducing valves are used to balance the system pressure; they are placed at the entrance of the buildings or residences. Pressure reducing valve drops the pressure down to 3-4 bars for residences.

Placing a strainer before pressure reducing valve will help to protect the product against possible damages. In those systems that more than one pressure reducing valve will be used, placing the strainer at the entrance of the building is important.

Water pressure behind the valve is adjusted by the screw pins at both sides of the valve. The manometer gauge compatible with the valve can be adjusted in the range of 0-6 bars. The gauge is provided with 3 bars of set pressure.

Material:
Body: Nickel coated brass

Connection:
Threaded

Max. Operating Temperature:
90 °C

Max. Operating Pressure:
16 bar

Nominal Diameter:
DN15 (1/2”) - DN50 (2”)

Manometer setting range (0-6 bar)

Applications:
- District water distribution lines, before water meter.]]></description>
										<content:encoded><![CDATA[Pressure reducing valves are used to balance the system pressure; they are placed at the entrance of the buildings or residences. Pressure reducing valve drops the pressure down to 3-4 bars for residences.

Placing a strainer before pressure reducing valve will help to protect the product against possible damages. In those systems that more than one pressure reducing valve will be used, placing the strainer at the entrance of the building is important.

Water pressure behind the valve is adjusted by the screw pins at both sides of the valve. The manometer gauge compatible with the valve can be adjusted in the range of 0-6 bars. The gauge is provided with 3 bars of set pressure.

Material:
Body: Nickel coated brass

Connection:
Threaded

Max. Operating Temperature:
90 °C

Max. Operating Pressure:
16 bar

Nominal Diameter:
DN15 (1/2”) - DN50 (2”)

Manometer setting range (0-6 bar)

Applications:
- District water distribution lines, before water meter.]]></content:encoded>
					
		
		