<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LV CABLES AND ACCESSORIES &#8211; VIBTIS</title>
	<atom:link href="https://www.vibtis.al/product-category/power-solution/energy-distribution/lv-equipment/lv-cables-and-accessories/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.vibtis.al</link>
	<description>Turnkey Solution - Investment - Services</description>
	<lastBuildDate>Tue, 04 Sep 2018 20:37:34 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.0.6</generator>
	<item>
		<title>BXO-HFTG Flame retardant halogen-free shipboard cable 0,6/1 kV</title>
		<link>https://www.vibtis.al/products/bxo-hftg-flame-retardant-halogen-free-shipboard-cable-06-1-kv/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:37:34 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4444</guid>

					<description><![CDATA[Application

Power and signal shipboard cable for fixed installation inside the ship acc. to IEC 60092-352 standard. Specially suitable for passenger ships because of improved characteristics under fire. Also applied at open sea platforms.

<b>advantages:</b>
- retained electric function of system within specified time
- halogen-free, no release of toxic and corrosive gases under fire
- reduced smoke manifestation under fire
- no flame propagation in vertical cable bundle, flame retardant
- resistant to oils and greases
- improved mechanical characteristics, resistant to scraping and vibrations
- smaller cable diameter and weight
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare or tinned copper conductor, multi wire stranded, class 2 acc. to IEC 60228 / HD 383 / DIN VDE 0295, round or sector</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>cross-linked polyethylene - XLPE, acc. to IEC 60092-351 (more recent mark for cross-linked polyethylene: PE-X), concentrically stranded cores, with or without green-yellow protective conductor</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Filler:</b></td>
<td>polyolefin based compound: or without filler</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>polyolefin, type SHF1 or SHF2 acc. to IEC 60092-359</td>
</tr>
<tr>
<td colspan="2" align="right"><b>sheath colour:</b></td>
<td>black or grey</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[Application

Power and signal shipboard cable for fixed installation inside the ship acc. to IEC 60092-352 standard. Specially suitable for passenger ships because of improved characteristics under fire. Also applied at open sea platforms.

<b>advantages:</b>
- retained electric function of system within specified time
- halogen-free, no release of toxic and corrosive gases under fire
- reduced smoke manifestation under fire
- no flame propagation in vertical cable bundle, flame retardant
- resistant to oils and greases
- improved mechanical characteristics, resistant to scraping and vibrations
- smaller cable diameter and weight
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare or tinned copper conductor, multi wire stranded, class 2 acc. to IEC 60228 / HD 383 / DIN VDE 0295, round or sector</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>cross-linked polyethylene - XLPE, acc. to IEC 60092-351 (more recent mark for cross-linked polyethylene: PE-X), concentrically stranded cores, with or without green-yellow protective conductor</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Filler:</b></td>
<td>polyolefin based compound: or without filler</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>polyolefin, type SHF1 or SHF2 acc. to IEC 60092-359</td>
</tr>
<tr>
<td colspan="2" align="right"><b>sheath colour:</b></td>
<td>black or grey</td>
</tr>
</tbody>
</table>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RG 11 A/U Coaxial cable</title>
		<link>https://www.vibtis.al/products/rg-11-a-u-coaxial-cable/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:36:36 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4442</guid>

					<description><![CDATA[Application

Coaxial cables are applied for broadband transmission of radio, TV, video and data signals. Applicable up to GHz-a level, with low attenuation and low signal distortion. RG11 coaxial cable is applied for inst. in video surveillance systems, but can be also used for larger distances. Foamed polyethylene of low dielectric constant enables high-speed signal diffusion, and good flexibility at installation. Permitted only indoor application, exceptionally also outdoor, under protection against sunlight.]]></description>
										<content:encoded><![CDATA[Application

Coaxial cables are applied for broadband transmission of radio, TV, video and data signals. Applicable up to GHz-a level, with low attenuation and low signal distortion. RG11 coaxial cable is applied for inst. in video surveillance systems, but can be also used for larger distances. Foamed polyethylene of low dielectric constant enables high-speed signal diffusion, and good flexibility at installation. Permitted only indoor application, exceptionally also outdoor, under protection against sunlight.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>-V(ZN)H Tight buffer cable for indoor application, with aramid reinforcement, watertight, with halogen-free sheath</title>
		<link>https://www.vibtis.al/products/vznh-tight-buffer-cable-for-indoor-application-with-aramid-reinforcement-watertight-with-halogen-free-sheath/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:35:45 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4440</guid>

					<description><![CDATA[Application

This distribution cable can be used for different indoor applications: LAN and WAN system backbones, links between central offices, backbones in information centers etc. Watertight cable, resistant to UV-irradiation, can be applied also outdoor in shorter segments. Can be laid in cable canals and on trays.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right" width="33%"><b>Fiber:</b></td>
<td>2 - 24 tightly buffered fibers, of 900 μm ± 50 μm</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Watertight membrane:</b></td>
<td>swelling tape</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Supporting element:</b></td>
<td>aramid threads, filled area around cable core</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>LSHF-FR halogen-free compound, resistant to UV-irradiation, of 1,1 mm thickness</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[Application

This distribution cable can be used for different indoor applications: LAN and WAN system backbones, links between central offices, backbones in information centers etc. Watertight cable, resistant to UV-irradiation, can be applied also outdoor in shorter segments. Can be laid in cable canals and on trays.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right" width="33%"><b>Fiber:</b></td>
<td>2 - 24 tightly buffered fibers, of 900 μm ± 50 μm</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Watertight membrane:</b></td>
<td>swelling tape</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Supporting element:</b></td>
<td>aramid threads, filled area around cable core</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>LSHF-FR halogen-free compound, resistant to UV-irradiation, of 1,1 mm thickness</td>
</tr>
</tbody>
</table>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cat. 5e U/UTP LAN cable with 4 pairs, category 5e, without screen</title>
		<link>https://www.vibtis.al/products/cat-5e-u-utp-lan-cable-with-4-pairs-category-5e-without-screen/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:34:33 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4438</guid>

					<description><![CDATA[Application

Cable applied in structured local networks of class D for high speed data and voice transmission, at primary, secondary (vertical) and tertiary (horizontal) level. Standardized for application up to 100 MHz (in certain configurations even up to 300 MHz).
Length of this cable in Ethernet networks is restricted at max. 100 m (ordinarily installed cable max. 90 m, with connecting cables up to 5 m at both ends). Can be laid in cable canals.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>copper (bare, single wired/solid), diameter 0,51 mm, AWG24</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>polyethylene (PE), external diameter 0,9 mm, per two conductors twisted in pairs</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>external diameter4,9 - 5,1 mm</td>
</tr>
<tr>
<td colspan="2" align="right">possible designs:</td>
<td>PVC or halogen-free (LSHF, LSOH, FRNC)</td>
</tr>
<tr>
<td colspan="2" align="right">sheath colour:</td>
<td>grey (RAL 7035)</td>
</tr>
<tr>
<td colspan="3"><b>Conductor colour marking:</b></td>
</tr>
<tr>
<td colspan="2" align="right">1. pair:</td>
<td>blue / white with blue line</td>
</tr>
<tr>
<td colspan="2" align="right">2. pair:</td>
<td>orange / white with orange line</td>
</tr>
<tr>
<td colspan="2" align="right">3. pair:</td>
<td>green / white with green line</td>
</tr>
<tr>
<td colspan="2" align="right">4. pair:</td>
<td>brown / white with brown line</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[Application

Cable applied in structured local networks of class D for high speed data and voice transmission, at primary, secondary (vertical) and tertiary (horizontal) level. Standardized for application up to 100 MHz (in certain configurations even up to 300 MHz).
Length of this cable in Ethernet networks is restricted at max. 100 m (ordinarily installed cable max. 90 m, with connecting cables up to 5 m at both ends). Can be laid in cable canals.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>copper (bare, single wired/solid), diameter 0,51 mm, AWG24</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>polyethylene (PE), external diameter 0,9 mm, per two conductors twisted in pairs</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>external diameter4,9 - 5,1 mm</td>
</tr>
<tr>
<td colspan="2" align="right">possible designs:</td>
<td>PVC or halogen-free (LSHF, LSOH, FRNC)</td>
</tr>
<tr>
<td colspan="2" align="right">sheath colour:</td>
<td>grey (RAL 7035)</td>
</tr>
<tr>
<td colspan="3"><b>Conductor colour marking:</b></td>
</tr>
<tr>
<td colspan="2" align="right">1. pair:</td>
<td>blue / white with blue line</td>
</tr>
<tr>
<td colspan="2" align="right">2. pair:</td>
<td>orange / white with orange line</td>
</tr>
<tr>
<td colspan="2" align="right">3. pair:</td>
<td>green / white with green line</td>
</tr>
<tr>
<td colspan="2" align="right">4. pair:</td>
<td>brown / white with brown line</td>
</tr>
</tbody>
</table>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>YSLY Flexible signal cable, PVC insulated and sheathed</title>
		<link>https://www.vibtis.al/products/ysly-flexible-signal-cable-pvc-insulated-and-sheathed/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:33:14 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4436</guid>

					<description><![CDATA[Application

Flexible signal cable used for surveillance and control of static or mobile devices in industry, electric plants or offices. Lightweight and relatively thin, resistant to medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strain. Installed in dry or damp premises, outdoor application only under protection against UV-irradiation. Not intended for laying in ground or water.]]></description>
										<content:encoded><![CDATA[Application

Flexible signal cable used for surveillance and control of static or mobile devices in industry, electric plants or offices. Lightweight and relatively thin, resistant to medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strain. Installed in dry or damp premises, outdoor application only under protection against UV-irradiation. Not intended for laying in ground or water.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LiYCY Electronic flexible cable, PVC insulated and sheathed, with Cu braid</title>
		<link>https://www.vibtis.al/products/liycy-electronic-flexible-cable-pvc-insulated-and-sheathed-with-cu-braid/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:30:03 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4434</guid>

					<description><![CDATA[Application

Flexible cable with protective screen against electromagnetic impacts, for transmission of analogue and digital signals, suitable for fixed and mobile installations in device production, for electronic, computer and measurement systems, in mobile and production conveyers, for office devices. Usage with shifting is only possible if not exposed to stress and mechanical loads. Laid in dry and damp premises, but outdoor application is not recommended, except in special cases under protection against direct sunlight. Not for direct laying in ground or water, not intended for supply purposes. Oil resistant.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295 (at some producers certain cross-sections with 7-wire conductors)</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>PVC compound of type TI2, acc. to DIN VDE 0281 part 1, conductors stranded in layers, core colour marking defined acc. to DIN 47100, but without repeating of colours</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Separator:</b></td>
<td>transparent plastic foil</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Electrostatic screen:</b></td>
<td>braid of tinned copper wires with approx. 85% overlap</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>PVC-compound TM2 acc. to DIN VDE 0281 part 1</td>
</tr>
<tr>
<td colspan="2" align="right"><b>sheath colour:</b></td>
<td>light grey (RAL 7001), grey (RAL 7032) or blue (RAL 5015)</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[Application

Flexible cable with protective screen against electromagnetic impacts, for transmission of analogue and digital signals, suitable for fixed and mobile installations in device production, for electronic, computer and measurement systems, in mobile and production conveyers, for office devices. Usage with shifting is only possible if not exposed to stress and mechanical loads. Laid in dry and damp premises, but outdoor application is not recommended, except in special cases under protection against direct sunlight. Not for direct laying in ground or water, not intended for supply purposes. Oil resistant.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295 (at some producers certain cross-sections with 7-wire conductors)</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>PVC compound of type TI2, acc. to DIN VDE 0281 part 1, conductors stranded in layers, core colour marking defined acc. to DIN 47100, but without repeating of colours</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Separator:</b></td>
<td>transparent plastic foil</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Electrostatic screen:</b></td>
<td>braid of tinned copper wires with approx. 85% overlap</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>PVC-compound TM2 acc. to DIN VDE 0281 part 1</td>
</tr>
<tr>
<td colspan="2" align="right"><b>sheath colour:</b></td>
<td>light grey (RAL 7001), grey (RAL 7032) or blue (RAL 5015)</td>
</tr>
</tbody>
</table>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>YYSch Telecommunications installation cable with PVC insulation and sheath</title>
		<link>https://www.vibtis.al/products/yysch-telecommunications-installation-cable-with-pvc-insulation-and-sheath/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:28:41 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4432</guid>

					<description><![CDATA[Application

The cable is applied for inner telecommunications installations in buildings, for door phones and similar. Laid in tubes or cable canals. Not for outdoor application or direct laying in ground or water, not intended for supply purposes.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare copper conductor, class 1 (solid) acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295, conductor diameter 0,6 mm</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>PVC</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>PVC</td>
</tr>
<tr>
<td colspan="2" align="right"><b>sheath colour:</b></td>
<td>grey (RAL 7001) or in ivory colour(1015)</td>
</tr>
<tr>
<td colspan="3"></td>
</tr>
<tr>
<td colspan="2" align="right"><b>Core colour marking:</b></td>
<td>acc. to ÖVE K 50</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[Application

The cable is applied for inner telecommunications installations in buildings, for door phones and similar. Laid in tubes or cable canals. Not for outdoor application or direct laying in ground or water, not intended for supply purposes.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare copper conductor, class 1 (solid) acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295, conductor diameter 0,6 mm</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>PVC</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>PVC</td>
</tr>
<tr>
<td colspan="2" align="right"><b>sheath colour:</b></td>
<td>grey (RAL 7001) or in ivory colour(1015)</td>
</tr>
<tr>
<td colspan="3"></td>
</tr>
<tr>
<td colspan="2" align="right"><b>Core colour marking:</b></td>
<td>acc. to ÖVE K 50</td>
</tr>
</tbody>
</table>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>J-H(St)H Halogen-free telecommunications installation cable, with improved properties under fire</title>
		<link>https://www.vibtis.al/products/j-hsth-halogen-free-telecommunications-installation-cable-with-improved-properties-under-fire/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:27:27 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4430</guid>

					<description><![CDATA[Application

Halogen-free installation cable for transmission of telephone and data (analogue and digital) signals, with improved properties under fire. Electrostatic screen protects transmission circuits against external disturbing electromagnetic impact. Suitable for fixed installation in dry or damp premises where people and material goods need to be protected in case of fire. Recommended for public and industrial facilities where a lot of people is gathering, and for facilities of high material value. Not for direct laying in ground or water, not for outdoor application (except when protected against sunlight), not intended for supply purposes.

<b>advantages:</b>
- halogen-free, no release of toxic and corrosive gases under fire
- reduced smoke manifestation under fire
- no flame propagation in vertical cable bundle , flame retardant
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare solid copper conductor, of 0,6 or 0,8 mm diameter</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>halogen-free polyolefin compound HI2, acc. to DIN VDE 0207 part 23, of 0,3 or 0,4 mm thickness, per four conductors are stranded in star-quad, each 5 quads are stranded in bundle, and bundles are stranded in layers, core colour marking is defined acc. to DIN VDE 0815</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Separator:</b></td>
<td>PEPT - plastic tape of poly (ethylene/propylene) or polyester tape</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Electrostatic screen:</b></td>
<td>aluminium - laminated polyester tape or tinned copper contact conductor of 0,6 or 0,8 mm diameter</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>halogen-free polyolefin compound HM2 acc. to DIN VDE 0207 part 24</td>
</tr>
<tr>
<td colspan="2" align="right"><b>sheath colour:</b></td>
<td>grey (RAL 7032)</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[Application

Halogen-free installation cable for transmission of telephone and data (analogue and digital) signals, with improved properties under fire. Electrostatic screen protects transmission circuits against external disturbing electromagnetic impact. Suitable for fixed installation in dry or damp premises where people and material goods need to be protected in case of fire. Recommended for public and industrial facilities where a lot of people is gathering, and for facilities of high material value. Not for direct laying in ground or water, not for outdoor application (except when protected against sunlight), not intended for supply purposes.

<b>advantages:</b>
- halogen-free, no release of toxic and corrosive gases under fire
- reduced smoke manifestation under fire
- no flame propagation in vertical cable bundle , flame retardant
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare solid copper conductor, of 0,6 or 0,8 mm diameter</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>halogen-free polyolefin compound HI2, acc. to DIN VDE 0207 part 23, of 0,3 or 0,4 mm thickness, per four conductors are stranded in star-quad, each 5 quads are stranded in bundle, and bundles are stranded in layers, core colour marking is defined acc. to DIN VDE 0815</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Separator:</b></td>
<td>PEPT - plastic tape of poly (ethylene/propylene) or polyester tape</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Electrostatic screen:</b></td>
<td>aluminium - laminated polyester tape or tinned copper contact conductor of 0,6 or 0,8 mm diameter</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Sheath:</b></td>
<td>halogen-free polyolefin compound HM2 acc. to DIN VDE 0207 part 24</td>
</tr>
<tr>
<td colspan="2" align="right"><b>sheath colour:</b></td>
<td>grey (RAL 7032)</td>
</tr>
</tbody>
</table>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>H05Z-K, H07Z-K Halogen-free fine wired conductor, with improved properties under fire</title>
		<link>https://www.vibtis.al/products/h05z-k-h07z-k-halogen-free-fine-wired-conductor-with-improved-properties-under-fire/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:25:59 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4428</guid>

					<description><![CDATA[Application

Halogen-free conductors used for installations in dry environment for wiring of lighting fixtures, tools and other devices in facilities where human lives or valuable property need to be protected against damages caused by fire. Laid on or under plaster, same as in closed installation canals. For inner wiring of switchboards and control panels up to the nominal voltage of 750/1000 V.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare or tinned copper conductor, fine wired stranded, class 5 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295</td>
</tr>
<tr>
<td colspan="2" align="right">at some producers:</td>
<td>separator between conductor and insulation</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>cross-linked thermoplastic halogen-free flame retardant polyolefin bond</td>
</tr>
<tr>
<td colspan="3"></td>
</tr>
<tr>
<td colspan="2" align="right"><b>Conductor color identification:</b></td>
<td>acc. to IEC 60446 i.e. EN 60446 (corresponding to DIN VDE 0293)</td>
</tr>
</tbody>
</table>
<b>advantages:</b>
- halogen-free, no release of toxic or corrosive gases under fire
- reduced smoke occurrence under fire]]></description>
										<content:encoded><![CDATA[Application

Halogen-free conductors used for installations in dry environment for wiring of lighting fixtures, tools and other devices in facilities where human lives or valuable property need to be protected against damages caused by fire. Laid on or under plaster, same as in closed installation canals. For inner wiring of switchboards and control panels up to the nominal voltage of 750/1000 V.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right"><b>Conductor:</b></td>
<td>bare or tinned copper conductor, fine wired stranded, class 5 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295</td>
</tr>
<tr>
<td colspan="2" align="right">at some producers:</td>
<td>separator between conductor and insulation</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>cross-linked thermoplastic halogen-free flame retardant polyolefin bond</td>
</tr>
<tr>
<td colspan="3"></td>
</tr>
<tr>
<td colspan="2" align="right"><b>Conductor color identification:</b></td>
<td>acc. to IEC 60446 i.e. EN 60446 (corresponding to DIN VDE 0293)</td>
</tr>
</tbody>
</table>
<b>advantages:</b>
- halogen-free, no release of toxic or corrosive gases under fire
- reduced smoke occurrence under fire]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NFA2X Self-supporting cable bundle 0,6/1 kV with XLPE-insulation</title>
		<link>https://www.vibtis.al/products/nfa2x-self-supporting-cable-bundle-06-1-kv-with-xlpe-insulation/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Tue, 04 Sep 2018 20:24:50 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=4426</guid>

					<description><![CDATA[Application

Self-supporting overhead cable bundle, applied for electric power distribution in low voltage metropolitan, suburban and rural networks, for public lighting and house connections. Laid on pillars, consoles and house fronts.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right" width="33%"><b>Phase conductor:</b></td>
<td>round Al conductor, multi wire stranded compacted (RM), class 2 acc. to HRN HD 383, phase conductors are marked with longitudinal protrusions (one, two or three)</td>
</tr>
<tr>
<td colspan="2" align="right" width="33%"><b>Neutral (supporting) conductor:</b></td>
<td>round conductor, multi wire stranded compacted (RM), class 2 acc. to HRN HD 383, of aluminium alloy</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>XLPE (cross-linked polyethylene, recent mark: PE-X) compound TIX-2 or TIX-5 acc. to HD 626 S1</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[Application

Self-supporting overhead cable bundle, applied for electric power distribution in low voltage metropolitan, suburban and rural networks, for public lighting and house connections. Laid on pillars, consoles and house fronts.
<table border="0" width="50%" cellpadding="2" align="left">
<tbody valign="top">
<tr>
<td colspan="2" align="right" width="33%"><b>Phase conductor:</b></td>
<td>round Al conductor, multi wire stranded compacted (RM), class 2 acc. to HRN HD 383, phase conductors are marked with longitudinal protrusions (one, two or three)</td>
</tr>
<tr>
<td colspan="2" align="right" width="33%"><b>Neutral (supporting) conductor:</b></td>
<td>round conductor, multi wire stranded compacted (RM), class 2 acc. to HRN HD 383, of aluminium alloy</td>
</tr>
<tr>
<td colspan="2" align="right"><b>Insulation:</b></td>
<td>XLPE (cross-linked polyethylene, recent mark: PE-X) compound TIX-2 or TIX-5 acc. to HD 626 S1</td>
</tr>
</tbody>
</table>]]></content:encoded>
					
		
		