<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>GUIDED WAVE RADAR &#8211; VIBTIS</title>
	<atom:link href="https://www.vibtis.al/product-category/oil-ang-gas/measurement-instrumentation/level-measurement-measurement-instrumentation/guided-wave-radar/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.vibtis.al</link>
	<description>Turnkey Solution - Investment - Services</description>
	<lastBuildDate>Sat, 08 Sep 2018 17:22:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.0.6</generator>
	<item>
		<title>Rosemount™ 5300 Level Transmitter &#8211; Guided Wave Radar</title>
		<link>https://www.vibtis.al/products/rosemount-5300-level-transmitter-guided-wave-radar/</link>
		
		<dc:creator><![CDATA[arber]]></dc:creator>
		<pubDate>Sat, 08 Sep 2018 17:22:34 +0000</pubDate>
				<guid isPermaLink="false">http://plagjiature.com/vibtis/?post_type=product&#038;p=5003</guid>

					<description><![CDATA[<div class="padded-container">
<div class="row">
<div class="col-xs-12 col-sm-6 col-md-6 right" data-slot-id="3">
<div class="product-description-wrapper
		" data-toggle-label="Read more...">
<p id="product_longdescription_726722" class="product-long-description">The Rosemount 5300 Level Transmitter is ideal for challenging measurements on liquids, slurries, and solids, offering state of the art reliability and safety features in level and interface applications. Rosemount 5300 offers several advantages such as easy installation, no need for calibration, and is unaffected by process conditions. Also, it is SIL 2 certified making it your first choice for safety applications. It has a robust construction and features powerful built-in diagnostics allowing you to focus on the essential part - your plant.</p>

<div class="navbar-wrapper"><nav class="navbar hidden-xs affix">
<div class="padded-container">
<ul class="nav navbar-nav">
 	<li style="list-style-type: none">
<ul class="nav navbar-nav">
 	<li id="documentsDrawingsNav" class="documents-and-drawings-nav"><a href="https://www.emerson.com/en-us/catalog/rosemount-5300-gwr-transmitter#section-documentsdrawingsgroup-3074457345619331778">DRAWINGS</a></li>
 	<li><a href="https://www.emerson.com/en-us/catalog/rosemount-5300-gwr-transmitter#section-utilitybeltgroup-3074457345619331778">CONTACT US</a></li>
</ul>
</li>
</ul>

<hr data-width-percentage="20.0" />

</div>
</nav></div>
<div id="section-specificationgroup-3074457345619331778" class="specifications section">
<div class="padded-container">
<div class="row">
<div class="col-xs-12 col-sm-4 col-md-3">
<h3>Specifications</h3>
</div>
<div id="specButton" class="col-xs-12 col-sm-8 col-md-9"></div>
</div>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Accuracy</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">± 0.12 in. (3 mm)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Repeatability</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">± 0.04 in. (1 mm)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Measurement Range</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Up to 164 ft (50 m)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Operating Pressure</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Full vacuum to 5000 psi (Full vacuum to 345 bar)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Operating Temperature</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">-320 to 752 °F (-196 to 400 °C)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Communication Protocol</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">4-20 mA/HART®, Foundation™ Fieldbus, Modbus®</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Safety</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">SIL 2 IEC 61508 certification
TÜV tested and WHG approved for overfill prevention</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Diagnostics</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Enhanced diagnostics enabling proactive maintenance</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Probe Types</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Rigid single lead, Segmented single lead, Flexible single lead, Rigid twin lead, Flexible twin lead, Coaxial, PTFE coated probes, Vapor probe</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Warranty</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Up to five years</dd>
</dl>
</div>
</div>
<div id="section-featuresgroup-3074457345619331778" class="features section">
<div class="padded-container">
<div class="row">
<div class="col-xs-12 col-sm-4 col-md-3">
<h3>Features</h3>
</div>
<div class="col-xs-12 col-sm-7 col-md-5">
<ul>
 	<li>Direct Switch Technology gives increased sensitivity, high reliability, and long measurement ranges</li>
 	<li>Signal Quality Metrics gives you the ability to work proactively with your level instrumentation</li>
 	<li>Probe End Projection offers greater level measurement reliability</li>
 	<li>Dynamic Vapor Compensation for improved plant heat rate</li>
 	<li>Verification reflector for unique level transmitter verification</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>]]></description>
										<content:encoded><![CDATA[<div class="padded-container">
<div class="row">
<div class="col-xs-12 col-sm-6 col-md-6 right" data-slot-id="3">
<div class="product-description-wrapper
		" data-toggle-label="Read more...">
<p id="product_longdescription_726722" class="product-long-description">The Rosemount 5300 Level Transmitter is ideal for challenging measurements on liquids, slurries, and solids, offering state of the art reliability and safety features in level and interface applications. Rosemount 5300 offers several advantages such as easy installation, no need for calibration, and is unaffected by process conditions. Also, it is SIL 2 certified making it your first choice for safety applications. It has a robust construction and features powerful built-in diagnostics allowing you to focus on the essential part - your plant.</p>

<div class="navbar-wrapper"><nav class="navbar hidden-xs affix">
<div class="padded-container">
<ul class="nav navbar-nav">
 	<li style="list-style-type: none">
<ul class="nav navbar-nav">
 	<li id="documentsDrawingsNav" class="documents-and-drawings-nav"><a href="https://www.emerson.com/en-us/catalog/rosemount-5300-gwr-transmitter#section-documentsdrawingsgroup-3074457345619331778">DRAWINGS</a></li>
 	<li><a href="https://www.emerson.com/en-us/catalog/rosemount-5300-gwr-transmitter#section-utilitybeltgroup-3074457345619331778">CONTACT US</a></li>
</ul>
</li>
</ul>

<hr data-width-percentage="20.0" />

</div>
</nav></div>
<div id="section-specificationgroup-3074457345619331778" class="specifications section">
<div class="padded-container">
<div class="row">
<div class="col-xs-12 col-sm-4 col-md-3">
<h3>Specifications</h3>
</div>
<div id="specButton" class="col-xs-12 col-sm-8 col-md-9"></div>
</div>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Accuracy</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">± 0.12 in. (3 mm)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Repeatability</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">± 0.04 in. (1 mm)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Measurement Range</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Up to 164 ft (50 m)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Operating Pressure</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Full vacuum to 5000 psi (Full vacuum to 345 bar)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Operating Temperature</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">-320 to 752 °F (-196 to 400 °C)</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Communication Protocol</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">4-20 mA/HART®, Foundation™ Fieldbus, Modbus®</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Safety</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">SIL 2 IEC 61508 certification
TÜV tested and WHG approved for overfill prevention</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Diagnostics</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Enhanced diagnostics enabling proactive maintenance</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Probe Types</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Rigid single lead, Segmented single lead, Flexible single lead, Rigid twin lead, Flexible twin lead, Coaxial, PTFE coated probes, Vapor probe</dd>
</dl>
<dl class="row generic-attr">
 	<dt class="col-xs-12 col-sm-4 col-md-3">Warranty</dt>
 	<dd class="col-xs-12 col-sm-8 col-md-9">Up to five years</dd>
</dl>
</div>
</div>
<div id="section-featuresgroup-3074457345619331778" class="features section">
<div class="padded-container">
<div class="row">
<div class="col-xs-12 col-sm-4 col-md-3">
<h3>Features</h3>
</div>
<div class="col-xs-12 col-sm-7 col-md-5">
<ul>
 	<li>Direct Switch Technology gives increased sensitivity, high reliability, and long measurement ranges</li>
 	<li>Signal Quality Metrics gives you the ability to work proactively with your level instrumentation</li>
 	<li>Probe End Projection offers greater level measurement reliability</li>
 	<li>Dynamic Vapor Compensation for improved plant heat rate</li>
 	<li>Verification reflector for unique level transmitter verification</li>